Post Offer Free
B&C Medical Technology Co.,Ltd  

Gold Index: 2853

You are here: home  > Patient Monitor  > Patient Monitor Patient Monitor

Patient Monitor Patient Monitor 

Payment Terms: T/T 
Place of Origin: Jiangsu, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: BCH800

patient monitor

Features
1.12.1'' color TFT LCD screen with multi channel waveforms display
2.Rechargeable high energy builr in Li Battery
3..Easy to learn,easy to use,simplified menus and delicated functions keys
4.Easy connectiong with central monitoring system
5.96 hours data storage
6.Suitable for adult,pediatrics and neonates
7.Monitors end-tidal CO2 and inspired CO2 accuracy at high respiration rates
8.Gas monitoring wirh cutting edge water filter tube

Technacal Specification      

ECG      

Number of Leads    3 or 5 leads

Lead View      User Slectable:I,II,III,aVR,aVL,aVF,V(5 Lead);I,II or III(3 lead)

Gain Slection  x1/4,x1/2,x1 and x2

Frequency Response      "Diagnostic:0.05 to 90HZ

Monitor:0.5 to 35 HZ

Surgery:1-15HZ"

Calibration Signa   1 (mV p-p),  Accuracy :±5%

ECG Signal Range ±8 m V ( Vp-p )

Review    Available

Pulse Oxemetry   

Range     0 to 100%

Resolution      1%

Accuracy "70% to 99% range ±2%

0 to 69%;undefined"

Method   Dual wavelength LED

Heart(Pulse) Rate

Source    User Slectable:Smart,ECG,Pleth,NIBP

Range     "Adult 15-300 bpm

Pediatric 15-350 bpm"

Accurancy      ±1bpm or ±1% whichever is greate

NIBP(Non-Invasive Blood Presure)     

Technique       Oscillometric during inflation

Range     Adult:40-270mmHg Pediatric:40-240mmHg Neonate:40-135mmHg"

Measurment cycle   <40 sec,typical

Cycles(Selectable)  2,3,5,10,15,30min 1,2,4hr

STAT model    5 minutes of continuous reading

Max Allowable

Cuff Presure"  "Adult:297±3 mmHg

Pediatric:240±3 mmHg

Neonate:147±3 mmHg"

Resolution      1mmHg

Transducer Accurancy    ±2mmHg or±2% of reading

Temperature 

Channels 2

Range,Accuracy   0°-50℃:±0.1℃

Display Resolution ±0.1℃

Proble     YSI 400 and YSI 700 Series

Respiration Rate  

Rate:       "Adult: 0 ~ 120 rpm

Neo/Ped 0 ~ 150 rpm"

Resolution      1rpm

Accuracy ± 2 breath/min

Trends   

Memory  96 hr at 30 second intervals for a NIBP reading every 5 mintues

Display   trabular;graphical

Interface  & Display    

Keys       9;memberance activated

Rotary Knob   Push or rotate;24 steps/turn

Screen     12,1 inch active color TFT

Resolution      Internal Display 800*600 pixels

Waveforms     9 Maxinum

Waveform Types    ECG Leads,I,II,III,aVR,aVL,aVF,V,Respiraion,CO2,Pletch

Sweep Speed  6.25,12.5,25 or 50 mm/sec

Languages      English;Chinese

Printer(option)    

Type       Thermal printer

Paper Speed    25 or 50 mm/sec

Configuration      

Standard:ECG, NIBP, SpO2, HR, Temp*2, Respiration      

Optional:ETCO2, INCO2, Respiration Rate and Prnter      

Ms. Cherry
 Ms. Cherry
Sales Manager
Tel: 86-516-82509209
Fax: 86-516-82509209
Mobile: 131 5122 1342
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

B&C Medical Technology Co.,Ltd [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Xuzhou
Province/State: Jiangsu
Country/Region: China (Mainland)

You May Like: